Supporting tube with HVI light plus Conductor

High-voltage-resistant, insulated down conductor for maintaining the separation distance from electrically conductive parts according to DIN EN 62305-3 (VDE 0185-305-3). For use up to an equivalent separation distance of s ≤ 60 cm (in air) or s ≤ 120 cm (solid building material).
Discreet supporting tube with pre-assembled, internal HVI light plus Conductor with low wind exposed surface.
Wide choice of lengths, from 6 m to 70 m.
The conductor cannot be returned as it is made to order.

HVI light plus Conductor inside the supporting tube with air-termination tip

Supporting tube with internal sealing end / EB spring element and air-termination tip, StSt, Ø10 mm, length 500 / 1,000 mm.

4 Produkte

Art.-Nr. 819672 HVI LI PL L6M SR1600 FSP500 GFK AL V2A

GTIN 4013364494527, Zolltarifnr. (EU): 85389099, Bruttogewicht: 8.10 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

HVI light plus Conductor inside the supporting tube with air-termination tip, grey colour
HVI light plus Conductor inside the supporting tube
High-voltage-resistant, insulated down conductor
for maintaining the separation distance
from electrically conductive parts
as per DIN EN 62305-3 (VDE 0185-305-3)
Equivalent separation distance s =< 60 cm (in air)
or s =< 120 cm (solid material).
The supporting tubes with HVI light plus are dimensioned to
Eurocode 1 (DIN EN 1991-1-4 + DIN EN 1991-1-4/NA).
HVI light plus Conductor Installed in the supporting tube, with special
internal sealing end and air-termination tip, Ø10 mm, length 500 mm
Material of supporting tube: GRP / Al
Length of supporting tube: 1600 mm
Transport length: 1600 mm
Diameter Ø conductor: 21 mm
Colour of conductor: grey ●
Material of conductor: Cu
Minimum order length: 6 m
Standard: DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Brand: DEHN
Type: HVI LI PL L6M SR1600 FSP500 GFK AL V2A
Part No.: 819672
or equivalent.

Zertifikate

 

Technische Daten

Length of air-termination tip 500 mm
Material of supporting tube GRP / Al
Length of supporting tube 1600 mm
Transport length 1600 mm
Outside diameter Ø 40 mm
Diameter Ø conductor 21 mm
Colour of conductor grey
Material of conductor Cu
Minimum order length 6 m
Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Artikel 819672 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 819672 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 819673 HVI LI PL L6M SR1600 FSP1000 GFK AL V2A

GTIN 4013364494534, Zolltarifnr. (EU): 85389099, Bruttogewicht: 8.37 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

HVI light plus Conductor inside the supporting tube with air-termination tip, grey colour
HVI light plus Conductor inside the supporting tube
High-voltage-resistant, insulated down conductor
for maintaining the separation distance
from electrically conductive parts
as per DIN EN 62305-3 (VDE 0185-305-3)
Equivalent separation distance s =< 60 cm (in air)
or s =< 120 cm (solid material).
The supporting tubes with HVI light plus are dimensioned to
Eurocode 1 (DIN EN 1991-1-4 + DIN EN 1991-1-4/NA).
HVI light plus Conductor Installed in the supporting tube, with special
internal sealing end and air-termination tip, Ø10 mm, length 1000 mm
Material of supporting tube: GRP / Al
Length of supporting tube: 1600 mm
Transport length: 1600 mm
Diameter Ø conductor: 21 mm
Colour of conductor: Grey ●
Material of conductor: Cu
Minimum order length: 6 m
Standard: DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Brand: DEHN
Type: HVI LI PL L6M SR1600 FSP1000 GFK AL V2A
Part No.: 819673
or equivalent.

Zertifikate

 

Technische Daten

Length of air-termination tip 1000 mm
Material of supporting tube GRP / Al
Length of supporting tube 1600 mm
Transport length 1600 mm
Outside diameter Ø 40 mm
Diameter Ø conductor 21 mm
Colour of conductor Grey
Material of conductor Cu
Minimum order length 6 m
Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Artikel 819673 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 819673 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 819674 HVI LI PL L6M SR2400 FSP500 GFK AL V2A

GTIN 4013364494541, Zolltarifnr. (EU): 85389099, Bruttogewicht: 9.10 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

HVI light plus Conductor inside the supporting tube with air-termination tip, grey colour
HVI light plus Conductor inside the supporting tube
High-voltage-resistant, insulated down conductor
for maintaining the separation distance
from electrically conductive parts
as per DIN EN 62305-3 (VDE 0185-305-3)
Equivalent separation distance s =< 60 cm (in air)
or s =< 120 cm (solid material).
The supporting tubes with HVI light plus are dimensioned to
Eurocode 1 (DIN EN 1991-1-4 + DIN EN 1991-1-4/NA).
HVI light plus Conductor Installed in the supporting tube, with special
internal sealing end and air-termination tip, Ø10 mm, length 500 mm
Material of supporting tube: GRP / Al
Length of supporting tube: 2400 mm
Transport length: 2400 mm
Diameter Ø conductor: 21 mm
Colour of conductor: Grey ●
Material of conductor: Cu
Minimum order length: 6 m
Standard: DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Brand: DEHN
Type: HVI LI PL L6M SR2400 FSP500 GFK AL V2A
Part No.: 819674
or equivalent.

Zertifikate

 

Technische Daten

Length of air-termination tip 500 mm
Material of supporting tube GRP / Al
Length of supporting tube 2400 mm
Transport length 2400 mm
Outside diameter Ø 40 mm
Diameter Ø conductor 21 mm
Colour of conductor Grey
Material of conductor Cu
Minimum order length 6 m
Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Artikel 819674 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 819674 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 819675 HVI LI PL L6M SR2400 FSP1000 GFK AL V2A

GTIN 4013364494558, Zolltarifnr. (EU): 85389099, Bruttogewicht: 9.37 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

HVI light plus Conductor inside the supporting tube with air-termination tip, grey colour
HVI light plus Conductor inside the supporting tube
High-voltage-resistant, insulated down conductor
for maintaining the separation distance
from electrically conductive parts
as per DIN EN 62305-3 (VDE 0185-305-3)
Equivalent separation distance s =< 60 cm (in air)
or s =< 120 cm (solid material).
The supporting tubes with HVI light plus are dimensioned to
Eurocode 1 (DIN EN 1991-1-4 + DIN EN 1991-1-4/NA).
HVI light plus Conductor installed in the supporting tube, with special
internal sealing end and air-termination tip, Ø10 mm, length 1,000 mm.
Material of supporting tube: GRP / Al
Length of supporting tube: 2400 mm
Transport length: 2400 mm
Diameter Ø conductor: 21 mm
Colour of conductor: Grey ●
Material of conductor: Cu
Minimum order length: 6 m
Standard: DIN IEC/TS 62561-8 (VDE V 0185-561-8)

Brand: DEHN
Type: HVI LI PL L6M SR2400 FSP1000 GFK AL V2A
Part No.: 819675
or equivalent.

Zertifikate

 

Technische Daten

Length of air-termination tip 1000 mm
Material of supporting tube GRP / Al
Length of supporting tube 2400 mm
Transport length 2400 mm
Outside diameter Ø 40 mm
Diameter Ø conductor 21 mm
Colour of conductor Grey
Material of conductor Cu
Minimum order length 6 m
Standard DIN IEC/TS 62561-8 (VDE V 0185-561-8)