Art.-Nr. 785906 PSA ESET S ID
GTIN 4013364476516, Zolltarifnr. (EU): 42032910, Bruttogewicht: 3.27 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 48 (S) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 9 (L) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 100 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785900 PSA ESET M ID
GTIN 4013364469556, Zolltarifnr. (EU): 42032910, Bruttogewicht: 3.27 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 50 (M) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 10 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 110 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785901 PSA ESET L ID
GTIN 4013364469563, Zolltarifnr. (EU): 42032910, Bruttogewicht: 3.27 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 54 (L) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 10 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 110 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785902 PSA ESET XL ID
GTIN 4013364469570, Zolltarifnr. (EU): 42032910, Bruttogewicht: 3.39 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 56 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 10 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 120 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785907 PSA ESET 2XL ID
GTIN 4013364476523, Zolltarifnr. (EU): 42032910, Bruttogewicht: 3.39 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 60 (2XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 11 (XXL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 130 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785908 PSA ESET S OD
GTIN 4013364476530, Zolltarifnr. (EU): 42032910, Bruttogewicht: 4.24 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 48 (S) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 9 (L) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 100 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785903 PSA ESET M OD
GTIN 4013364469587, Zolltarifnr. (EU): 42032910, Bruttogewicht: 4.24 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 50 (M) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 10 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 110 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785904 PSA ESET L OD
GTIN 4013364469594, Zolltarifnr. (EU): 42032910, Bruttogewicht: 4.34 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 54 (L) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 10 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 110 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785905 PSA ESET XL OD
GTIN 4013364469600, Zolltarifnr. (EU): 42032910, Bruttogewicht: 4.44 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 56 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 10 (XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 120 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |
Art.-Nr. 785909 PSA ESET 2XL OD
GTIN 4013364476547, Zolltarifnr. (EU): 42032910, Bruttogewicht: 4.44 kg, VPE: 1.00 pc(s)
Technische Daten
Protective jacket/trousers | 60 (2XL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
Protective gloves | 11 (XXL) |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 320 kJ |
- Arc Rating – ATPV (Open Arc Test) | 32.8 cal / cm2 |
- PPE category (NFPA 70E) | PPE 3 |
Face shield | transparent |
- Arc fault protection class (box test 7 kA / 0.5 s – single-pole) | APC 2 |
- Arc energy (Warc or WLBP ) | 318 kJ |
- Visible light transmittance (VLT) | 74.4 ... 100 % |
- Light transmittance class | 0 |
Safety helmet for electricians | yellow |
- Nominal voltage up to (UN ) | 1000 V |
Belt | 130 cm |
Microfibre bag | 450 x 400 mm |
Storage bag | Ø300, 500 mm |