Ihre Services im Dashboard..
Registriert nutzen Sie das komplette Angebot.

Connecting Clamps for Foundation Earth Electrodes and Reinforcements

For connecting round and flat conductors in the concrete foundation or reinforcing steel meshes and reinforcements with round and flat conductors.

Arrangement:
(II) = parallel
(+) = cross

Connecting clamp with thrust bracket

For T, cross and parallel connections.

1 Produkt

Art.-Nr. 308031 VK DB 6.20 8.10 FL30 BSB STBL

GTIN 4013364136571, Zolltarifnr. (EU): 85359000, Bruttogewicht: 239.60 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Connecting clamp with thrust bracket, St/bare
Connecting clamp with thrust bracket for connecting round and flat conductors in the concrete
foundation or reinforcing steel meshes and reinforcements with
round and flat conductors
For T, cross and parallel connections
Material: St/bare
Clamping range Rd / Rd: (+/II) 6-20 / 8-10 mm
Clamping range Rd / Fl: (+/II) 6-20 / 30 x 3-4 mm
Clamping range Fl / Fl: (+/II) 30 x 3-4 / 30 x 3-4 mm
Standard: EN 62561-1

Brand: DEHN
Type: VK DB 6.20 8.10 FL30 BSB STBL
Part No.: 308031
or equivalent.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd (+/II) 6-20 / 8-10 mm
Clamping range Rd / Fl (+/II) 6-20 / 30 x 3-4 mm
Clamping range Fl / Fl (+/II) 30 x 3-4 / 30 x 3-4 mm
Short-circuit current (a.c. 50 Hz / d.c.) (1 s; ≤ 300 °C) 8.4 kA
Standard EN 62561-1
*) For exact assignment see test certificate.

Artikel 308031 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308031 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Connecting clamp MAXI with thrust bracket

For T, cross and parallel connections.

1 Produkt

Art.-Nr. 308036 VK DB 20.32 8.10 FL40 BSB STBL

GTIN 4013364136588, Zolltarifnr. (EU): 85359000, Bruttogewicht: 275.60 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

MAXI connecting clamp with thrust bracket, St/bare
Connecting clamp with thrust bracket for connecting round and flat conductors
in the concrete foundation or reinforcing steel meshes
and reinforcements with round and flat conductors
For T, cross and parallel connections
Material: St/bare
Clamping range Rd / Rd: (+/II) 20-32 / 8-10 mm
Clamping range Rd / Fl: (+/II) 20-32 / 40 x 4-5 mm
Standard: EN 62561-1

Brand: DEHN
Type: VK DB 20.32 8.10 FL40 BSB STBL
Part No.: 308036
or equivalent.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd (+/II) 20-32 / 8-10 mm
Clamping range Rd / Fl (+/II) 20-32 / 40 x 4-5 mm
Short-circuit current (a.c. 50 Hz / d.c.) (1 s; ≤ 300 °C) 14.0 kA
Standard EN 62561-1
*) For exact assignment see test certificate.

Artikel 308036 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308036 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Connecting clamp without thrust bracket

For cross connections.

1 Produkt

Art.-Nr. 308032 VK 6.20 FL30 BSB STBL

GTIN 4013364152823, Zolltarifnr. (EU): 85359000, Bruttogewicht: 178.50 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Connecting clamp without thrust bracket, St/bare
Connecting clamp for foundation earth electrodes
For connecting round and flat conductors in the concrete foundation
For cross connections, without having to insert the conductor

Material: St/bare
Clamping range Rd / Fl: (+) 6-20 / 30 x 3-4 mm
Clamping range Fl / Fl: (+/II) 30 x 3-4 / 30 x 3-4 mm
Standard: EN 62561-1

Brand: DEHN
Type: VK 6.20 FL30 BSB STBL
Part No.: 308032
or equivalent.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Fl (+) 6-20 / 30 x 3-4 mm
Clamping range Fl / Fl (+/II) 30 x 3-4 / 30 x 3-4 mm
Short-circuit current (a.c. 50 Hz / d.c.) (1 s; ≤ 300 °C) 7.0 kA
Standard EN 62561-1
*) For exact assignment see test certificate.

Artikel 308032 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308032 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Connecting clamp MAXI without thrust bracket

For cross connections.

1 Produkt

Art.-Nr. 308037 VK 20.32 FL40 BSB STBL

GTIN 4013364154704, Zolltarifnr. (EU): 85359000, Bruttogewicht: 218.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Connecting clamp MAXI without thrust bracket, St/bare
Connecting clamp for foundation earth electrodes
For connecting round and flat conductors in the concrete foundation
For cross connections, without having to insert the conductor

Material: St/bare
Clamping range Rd / Fl: (+) 20-32 / 30 x 3-40 x 5 mm
Standard: EN 62561-1

Brand: DEHN
Type: VK 20.32 FL40 BSB STBL
Part No.: 308037
or equivalent.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Fl (+) 20-32 / 30 x 3-40 x 5 mm
Standard EN 62561-1
*) For exact assignment see test certificate.