BLITZDUCTORconnect – Compact
- For protecting data bus interfaces as well as measuring and control circuits
- High discharge capacity of 3 kA (10/350 µs), 10 kA (8/20 µs)
- Max. impulse current carrying capability (8/20 µs) Imax up to 20 kA
- Low voltage protection level, also capable of protecting terminal equipment
- Fast and simple cable connection thanks to push-in connection technology
- High system availability thanks to fail-safe performance
- LifeCheck and visual status indication integrated in the module
- Simple remote signalling of the status with the help of an optional remote signalling unit
- Vibration and shock-tested for safe operation
Details
Art.-Nr. 927910 BCO CL2 B 180
GTIN 4013364411739, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
Technische Daten
SPD class | A |
Max. continuous operating voltage (d.c.) (UC ) | 180 V |
Nominal current (IL ) | 1.2 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 0 ohms |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927922 BCO CL2 BE 12
GTIN 4013364411951, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | M |
Max. continuous operating voltage (d.c.) (UC ) | 15 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 1.4 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927924 BCO CL2 BE 24
GTIN 4013364411968, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | M |
Max. continuous operating voltage (d.c.) (UC ) | 33 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 3.4 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927925 BCO CL2 BE 48
GTIN 4013364411975, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | M |
Max. continuous operating voltage (d.c.) (UC ) | 54 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 5 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927942 BCO CL2 BD 12
GTIN 4013364411777, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 15 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 2.6 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927944 BCO CL2 BD 24
GTIN 4013364411784, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 36 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 5.8 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927945 BCO CL2 BD 48
GTIN 4013364411807, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 56 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 7.2 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927970 BCO CL2 BE HF 5
GTIN 4013364411982, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
Technische Daten
SPD class | M |
Max. continuous operating voltage (d.c.) (UC ) | 8.5 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
Art.-Nr. 927971 BCO CL2 BD HF 5
GTIN 4013364411999, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 8.5 V |
Nominal current at 70 °C (IL ) | 0.75 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 100 MHz |
Approvals | UL 497B, CSA, ATEX, IECEx, CCC, SIL |
BCO CL2 E
Space-saving, compact surge arrester with a width of 6 mm and push-in connection technology with status indication. Finely limiting, single-stage surge protection with powerful diodes for protecting two single cores sharing a common reference potential as well as unbalanced interfaces.
3 Produkte
Art.-Nr. 927987 BCO CL2 E 12
GTIN 4013364485754, Zolltarifnr. (EU): 85363010, Bruttogewicht: 55.94 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | W |
Max. continuous operating voltage (d.c.) (UC ) | 15 V |
Nominal current at 60 °C (IL ) | 10 A |
Nominal current at 80 °C (IL ) | 6 A |
C1 Total nominal discharge current (8/20 µs) (In ) | 3 kA |
Series resistance per line | 0 ohms |
Approvals | UL 497B |
Art.-Nr. 927988 BCO CL2 E 24
GTIN 4013364485747, Zolltarifnr. (EU): 85363010, Bruttogewicht: 56.04 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | W |
Max. continuous operating voltage (d.c.) (UC ) | 33 V |
Nominal current at 60 °C (IL ) | 10 A |
Nominal current at 80 °C (IL ) | 6 A |
C1 Total nominal discharge current (8/20 µs) (In ) | 1.2 kA |
Series resistance per line | 0 ohms |
Approvals | UL 497B |
Art.-Nr. 927989 BCO CL2 E 48
GTIN 4013364485761, Zolltarifnr. (EU): 85363010, Bruttogewicht: 36.58 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | W |
Max. continuous operating voltage (d.c.) (UC ) | 58 V |
Nominal current at 60 °C (IL ) | 10 A |
Nominal current at 80 °C (IL ) | 6 A |
C1 Total nominal discharge current (8/20 µs) (In ) | 0.8 kA |
Series resistance per line | 0 ohms |
Approvals | UL 497B |
Art.-Nr. 927954 BCO CL4 BC 24
GTIN 4013364485730, Zolltarifnr. (EU): 85363010, Bruttogewicht: 80.10 g, VPE: 1.00 pc(s)
Technische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 36 V |
Nominal current at 80 °C (IL ) | 3 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 2.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 20 kA |
Series resistance per line | 0 ohms |
Approvals | UL 497B |
Art.-Nr. 927408 BCO CL2 BD HC10A 24
GTIN 4013364463653, Zolltarifnr. (EU): 85363010, Bruttogewicht: 68.30 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 45 V |
Nominal current at 80 °C (IL ) | 10 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 2.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 20 kA |
Series resistance per line | 0 ohms |
Approvals | UL 497B, SIL |
Art.-Nr. 927984 BCO CL2 BD EX 24
GTIN 4013364412002, Zolltarifnr. (EU): 85363010, Bruttogewicht: 57.86 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD class | L |
Max. continuous operating voltage (d.c.) (UC ) | 36 V |
Nominal current at 80 °C (IL ) | 0.5 A |
D1 Lightning impulse current (10/350 µs) per line (Iimp ) | 1.5 kA |
C2 Total nominal discharge current (8/20 µs) (In ) | 10 kA |
Series resistance per line | 1 ohms |
Cut-off frequency line-line (fG ) | 3.5 MHz |
Approvals | ATEX, IECEx, CCC, SIL |