Protection Module for DEHNsecure modular

  • Spark gap technology particularly suited for use in d.c. circuits
  • Operating state / fault indication by green / red indicator flag in the inspection window
  • Easy replacement of protection modules without tools due to module locking system with module release button

DSE M Spark-Gap-Based Protection Module

Spark-gap-based protection module

3 Produkte

Art.-Nr. 971001 DSE MOD 60

GTIN 4013364138605, Zolltarifnr.: 85363090, Bruttogewicht: 151.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DSE MOD 60 spark-gap-based protection module
Spark-gap-based protection module for
coordinated single-pole type 1 arresters of
the Red/Line series according to EN 61643-11
Spark gap technology particularly suitable for use
in d.c. circuits
Fault indication
Max. continuous operating voltage: 60 V d.c.
Lightning impulse current: 25 kA
Short-circuit strength in case of
max. mains-side overcurrent protection (d.c.): 25 kA

Brand: DEHN
Type: DSE MOD 60
Part No.: 971001
or equivalent.

Zertifikate

 

Technische Daten

Max. continuous operating voltage (d.c.) (UC ) 60 V
Lightning impulse current (10/350 µs) (Iimp ) 25 kA

Artikel 971001 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 971001 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 971002 DSE MOD 220

GTIN 4013364133655, Zolltarifnr.: 85363090, Bruttogewicht: 118.20 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DSE MOD 220 spark-gap-based protection module
Spark-gap-based protection module for
coordinated single-pole type 1 arresters of
the Red/Line series according to EN 61643-11
Spark gap technology particularly suitable for use
in d.c. circuits
Fault indication
Max. continuous operating voltage: 220 V d.c.
Lightning impulse current: 25 kA
Short-circuit strength in case of
max. mains-side overcurrent protection (d.c.): 25 kA

Brand: DEHN
Type: DSE MOD 220
Part No.: 971002
or equivalent.

Zertifikate

 

Technische Daten

Max. continuous operating voltage (d.c.) (UC ) 220 V
Lightning impulse current (10/350 µs) (Iimp ) 25 kA

Artikel 971002 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 971002 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 971003 DSE MOD 242

GTIN 4013364144491, Zolltarifnr.: 85363090, Bruttogewicht: 120.50 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DSE MOD 242 spark-gap-based protection module
Spark-gap-based protection module for
coordinated single-pole type 1 arresters of
the Red/Line series according to EN 61643-11
Spark gap technology particularly suitable for use
in d.c. circuits
Fault indication
Max. continuous operating voltage: 242 V d.c.
Lightning impulse current: 25 kA
Short-circuit strength in case of
max. mains-side overcurrent protection (d.c.): 25 kA

Brand: DEHN
Type: DSE MOD 242
Part No.: 971003
or equivalent.

Zertifikate

 

Technische Daten

Max. continuous operating voltage (d.c.) (UC ) 242 V
Lightning impulse current (10/350 µs) (Iimp ) 25 kA

Artikel 971003 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 971003 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

DSE PE Spark-Gap-Based Protection Module

Spark-gap-based protection module

1 Produkt

Art.-Nr. 971010 DSE MOD PE 60

GTIN 4013364138636, Zolltarifnr.: 85363090, Bruttogewicht: 183.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DSE MOD PE 60 spark-gap-based protection module
PE spark-gap-based protection module for
coordinated single-pole type 1 arresters of
the Red/Line series according to EN 61643-11
Spark gap technology particularly suitable for use
in d.c. circuits
Fault indication
Max. continuous operating voltage: 60 V d.c.
Lightning impulse current: 50 kA
Short-circuit strength in case of
max. mains-side overcurrent protection (d.c.): 25 kA

Brand: DEHN
Type: DSE MOD PE 60
Part No.: 971010
or equivalent.

Zertifikate

 

Technische Daten

Max. continuous operating voltage (d.c.) (UC ) 60 V
Lightning impulse current (10/350 µs) (Iimp ) 50 kA

Artikel 971010 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 971010 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben

Cookie-Einstellungen

Wir verwenden Cookies, um Ihnen ein optimales Webseiten-Erlebnis zu bieten. Dazu zählen Cookies, die für den Betrieb der Seite und für die Steuerung unserer kommerziellen Unternehmensziele notwendig sind, sowie solche, die lediglich zu anonymen Statistikzwecken, für Komforteinstellungen oder zur Anzeige personalisierter Inhalte genutzt werden. Sie können selbst entscheiden, welche Kategorien Sie zulassen möchten. Bitte beachten Sie, dass auf Basis Ihrer Einstellungen womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen. Weitere Informationen finden Sie in unseren Datenschutzerklärung.
Wenn Sie in die Nutzung von Cookies eingewilligt haben, können Sie dies jederzeit nach Klick auf den Link "Cookie-Einstellungen ändern" im Footer der Seite widerrufen.

  • Details anzeigen Details ausblenden
    Notwendig

    Diese Cookies sind für den Betrieb der Seite unbedingt notwendig und ermöglichen beispielsweise sicherheitsrelevante Funktionalitäten. Außerdem können wir mit dieser Art von Cookies ebenfalls erkennen, ob Sie in Ihrem Profil eingeloggt bleiben möchten, um Ihnen unsere Dienste bei einem erneuten Besuch unserer Seite schneller zur Verfügung zu stellen.

    Statistik & Marketing

    Um unser Angebot und unsere Webseite weiter zu verbessern, erfassen wir anonymisierte Daten für Statistiken und Analysen. Mithilfe dieser Cookies können wir beispielsweise die Besucherzahlen und den Effekt bestimmter Seiten unseres Web-Auftritts ermitteln und unsere Inhalte optimieren.