Roof Conductor Holders with Tension Spring for Ridge and Hip Tiles

For fixing air-termination conductors on the ridge, e.g. of tile roofs.

SPANNsnap light

Fixed with a StSt tension spring, with conductor holder DEHNsnap, loose conductor routing, laterally adjustable.

2 Produkte

Art.-Nr. 204469 DLH SSL 8 H16 FG180.280 GR V2A

GTIN 4013364124851, Zolltarifnr. (EU): 85389099, Bruttogewicht: 67.20 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNsnap light, StSt, height of conductor holder: 16 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNsnap fixed with a stainless steel tension spring, with DEHNsnap conductor holder,
loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 16 mm
Material of conductor holder: plastic
Colour of conductor holder: grey ●

Brand: DEHN
Type: DLH SSL 8 H16 FG180.280 GR V2A
Part No.: 204469
or equivalent.

Zertifikate

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 16 mm
Material of conductor holder plastic
Colour of conductor holder grey
Conductor support Rd 8 mm

Artikel 204469 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 204469 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 204449 DLH SSL 8 H36 FG180.280 GR V2A

GTIN 4013364124837, Zolltarifnr. (EU): 85389099, Bruttogewicht: 70.30 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNsnap light, StSt, height of conductor holder: 36 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNsnap light fixed with a stainless steel tension spring, with DEHNsnap conductor holder,
loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 36 mm
Material of conductor holder: plastic
Colour of conductor holder: grey ●

Brand: DEHN
Type: DLH SSL 8 H36 FG180.280 GR V2A
Part No.: 204449
or equivalent.

Zertifikate

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 36 mm
Material of conductor holder plastic
Colour of conductor holder grey
Conductor support Rd 8 mm

Artikel 204449 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 204449 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

SPANNsnap

Fixed with a StSt tension spring, with conductor holder DEHNsnap, loose conductor routing, laterally adjustable.

4 Produkte

Art.-Nr. 204269 DLH SS 8 H16 FG180.280 GR V2A

GTIN 4013364035812, Zolltarifnr. (EU): 85389099, Bruttogewicht: 68.60 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNsnap, StSt, height of conductor holder: 16 mm, grey
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNsnap light fixed with a stainless steel tension spring, with DEHNsnap conductor holder,
loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 16 mm
Material of conductor holder: plastic
Colour of conductor holder: grey ●

Brand: DEHN
Type: DLH SS 8 H16 FG180.280 GR V2A
Part No.: 204269
or equivalent.

Zertifikate

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 16 mm
Material of conductor holder plastic
Colour of conductor holder grey
Conductor support Rd 8 mm

Artikel 204269 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 204269 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 204267 DLH SS 8 H16 FG180.280 BR CU

GTIN 4013364035805, Zolltarifnr. (EU): 85389099, Bruttogewicht: 74.60 g, VPE: 25.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Gable roofs - SPANNsnap, Cu, height of conductor holder: 16 mm, brown
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNsnap light fixed with a stainless steel tension spring, with DEHNsnap conductor holder,
loose conductor routing, laterally adjustable
Material of roof conductor holder: Cu
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 16 mm
Material of conductor holder: plastic
Colour of conductor holder: brown ●

Brand: DEHN
Type: DLH SS 8 H16 FG180.280 BR CU
Part No.: 204267
or equivalent.

Zertifikate

 

Technische Daten

Material of roof conductor holder Cu
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 16 mm
Material of conductor holder plastic
Colour of conductor holder brown
Conductor support Rd 8 mm

Artikel 204267 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 204267 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 204249 DLH SS 8 H36 FG180.280 GR V2A

GTIN 4013364041790, Zolltarifnr. (EU): 85389099, Bruttogewicht: 72.60 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNsnap, StSt, height of conductor holder: 36 mm, grey
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNsnap fixed with a stainless steel tension spring, with DEHNsnap conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 36 mm
Material of conductor holder: plastic
Colour of conductor holder: grey ●

Brand: DEHN
Type: DLH SS 8 H36 FG180.280 GR V2A
Part No.: 204249
or equivalent.

Zertifikate

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 36 mm
Material of conductor holder plastic
Colour of conductor holder grey
Conductor support Rd 8 mm

Artikel 204249 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 204249 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 204247 DLH SS 8 H36 FG180.280 BR CU

GTIN 4013364041806, Zolltarifnr. (EU): 85389099, Bruttogewicht: 76.60 g, VPE: 25.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Gable roofs - SPANNsnap, Cu, height of conductor holder: 36 mm, brown
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNsnap fixed with a stainless steel tension spring, with DEHNsnap conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: Cu
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 36 mm
Material of conductor holder: plastic
Colour of conductor holder: brown ●

Brand: DEHN
Type: DLH SS 8 H36 FG180.280 BR CU
Part No.: 204247
or equivalent.

Zertifikate

 

Technische Daten

Material of roof conductor holder Cu
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 36 mm
Material of conductor holder plastic
Colour of conductor holder brown
Conductor support Rd 8 mm

Artikel 204247 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 204247 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

SPANNgrip light

Fixed with a StSt tension spring, with conductor holder DEHNgrip, loose conductor routing, laterally adjustable.

2 Produkte

Art.-Nr. 206439 DLH SGL 8 H20 FG180.280 V2A

GTIN 4013364124875, Zolltarifnr. (EU): 85389099, Bruttogewicht: 76.40 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNgrip light, StSt, height of conductor holder: 20 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNgrip light fixed with a stainless steel tension spring, with DEHNsnap conductor holder, loose conductor routing, laterally adjustable

Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 20 mm
Material of conductor holder: StSt

Brand: DEHN
Type: DLH SGL 8 H20 FG180.280 V2A
Part No.: 206439
or equivalent.

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 20 mm
Material of conductor holder StSt
Conductor support Rd 8 mm
Standard EN 62561-4

Artikel 206439 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 206439 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 206449 DLH SGL 8 H32 FG180.280 V2A

GTIN 4013364124899, Zolltarifnr. (EU): 85389099, Bruttogewicht: 82.10 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNgrip light, StSt, height of conductor holder: 32 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge,e.g. for tile roofs
SPANNgrip light fixed with a StSt tension spring, with DEHNsnap conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 32 mm
Material of conductor holder: StSt

Brand: DEHN
Type: DLH SGL 8 H32 FG180.280 V2A
Part No.: 206449
or equivalent.

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 32 mm
Material of conductor holder StSt
Conductor support Rd 8 mm
Standard EN 62561-4

Artikel 206449 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 206449 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

SPANNgrip

Fixed with a StSt tension spring, with conductor holder DEHNgrip, loose conductor routing, laterally adjustable.

4 Produkte

Art.-Nr. 206239 DLH SG 8 H20 FG180.280 V2A

GTIN 4013364042650, Zolltarifnr. (EU): 85389099, Bruttogewicht: 78.60 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNgrip, StSt, height of conductor holder: 20 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNgrip fixed with a stainless steel tension spring, with DEHNgrip conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 20 mm
Material of conductor holder: StSt

Brand: DEHN
Type: DLH SG 8 H20 FG180.280 V2A
Part No.: 206239
or equivalent.

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 20 mm
Material of conductor holder StSt
Conductor support Rd 8 mm
Standard EN 62561-4

Artikel 206239 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 206239 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 206237 DLH SG 8 H20 FG180.280 CU

GTIN 4013364077300, Zolltarifnr. (EU): 85389099, Bruttogewicht: 85.60 g, VPE: 25.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Gable roofs - SPANNgrip, Cu, height of conductor holder: 20 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNgrip fixed with a stainless steel tension spring, with DEHNgrip conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: Cu
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 20 mm
Material of conductor holder: Cu

Brand: DEHN
Type: DLH SG 8 H20 FG180.280 CU
Part No.: 206237
or equivalent.

 

Technische Daten

Material of roof conductor holder Cu
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 20 mm
Material of conductor holder Cu
Conductor support Rd 8 mm
Standard EN 62561-4

Artikel 206237 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 206237 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 206249 DLH SG 8 H32 FG180.280 V2A

GTIN 4013364042803, Zolltarifnr. (EU): 85389099, Bruttogewicht: 84.60 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Gable roofs - SPANNgrip, StSt, height of conductor holder: 32 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNgrip fixed with a stainless steel tension spring, with DEHNgrip conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: StSt
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 32 mm
Material of conductor holder: StSt

Brand: DEHN
Type: DLH SG 8 H32 FG180.280 V2A
Part No.: 206249
or equivalent.

 

Technische Daten

Material of roof conductor holder StSt
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 32 mm
Material of conductor holder StSt
Conductor support Rd 8 mm
Standard EN 62561-4

Artikel 206249 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 206249 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 206247 DLH SG 8 H32 FG180.280 CU

GTIN 4013364078574, Zolltarifnr. (EU): 85389099, Bruttogewicht: 96.60 g, VPE: 25.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Gable roofs - SPANNgrip, Cu, height of conductor holder: 32 mm
Roof conductor holder with tension spring for ridge and hip tiles for fixing air-termination conductors on the ridge, e.g. for tile roofs
SPANNgrip fixed with a stainless steel tension spring, with DEHNgrip conductor holder, loose conductor routing, laterally adjustable
Material of roof conductor holder: Cu
Clamping range of ridge tile width: 180-280 mm
Height of conductor holder: 32 mm
Material of conductor holder: Cu

Brand: DEHN
Type: DLH SG 8 H32 FG180.280 CU
Part No.: 206247
or equivalent.

 

Technische Daten

Material of roof conductor holder Cu
Clamping range of ridge tile width 180-280 mm
Height of conductor holder (h1) 32 mm
Material of conductor holder Cu
Conductor support Rd 8 mm
Standard EN 62561-4

Artikel 206247 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 206247 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben