Ihre Services im Dashboard..
Registriert nutzen Sie das komplette Angebot.

Összekötő kapocs betonvasalásokhoz

Clamps for connecting reinforcing steel mesh or bar with round and flat conductors

Arrangement:
(II) = parallel
(+) = cross

Details

Figure 3: U-bolt clamp Part No. 308 046
lorem ipsum
Figure 5: Connecting clamp Part No. 308 035
lorem ipsum
Figure 4: U-bolt clamp with cable lug
lorem ipsum
Figure 1: Diameters of reinforcing steels.
Ref.: Steel for the reinforcement of concrete according to DIN EN 10080:2005.
lorem ipsum
Figure 3: U-bolt clamp Part No. 308 045
lorem ipsum

For T, cross and parallel connections

1 Produkt

Art.-Nr. 308025 VK A UNI ST

GTIN 4013364035881, Zolltarifnr. (EU): 85359000, Bruttogewicht: 102.00 g, VPE: 50.00 db.


Abbildungen

Weitere Information

Connecting clamps for reinforcements, St/tZn
Connecting clamp for connecting reinforcing steel
mesh and bar with round conductors
For T, cross and parallel connections
Material: St/tZn
Clamping range Rd / Rd: (+) 6-10 / 6-10 mm
Clamping range Rd / Fl: (+) 6-10 / 30 mm
Clamping range Fl / Fl: (II) 30 / 30 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 9 kA

Gyártó: DEHN
Típus: VK A UNI ST
Cikksz.: 308025
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/tZn
Clamping range Rd / Rd (+) 6-10 / 6-10 mm
Clamping range Rd / Fl (+) 6-10 / 30 mm
Clamping range Fl / Fl (II) 30 / 30 mm
Screw di M10 x 25 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 9 kA

Artikel 308025 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308025 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

For T, cross and parallel connections

1 Produkt

Art.-Nr. 308026 VK 6.10 FL30 FL30 BSB STTZN

GTIN 4013364035874, Zolltarifnr. (EU): 85359000, Bruttogewicht: 111.00 g, VPE: 25.00 db.


Abbildungen

Weitere Information

Connecting clamps for reinforcements, St/tZn
Connecting clamp for connecting reinforcing steel
mesh and bar with flat conductors
For T, cross and parallel connections
Material: St/tZn
Clamping range Rd / Fl: (+) 6-10 / 30 mm
Clamping range Fl / Fl: (+ / II) 30 / 30 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 13 kA

Gyártó: DEHN
Típus: VK 6.10 FL30 FL30 BSB STTZN
Cikksz.: 308026
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/tZn
Clamping range Rd / Fl (+) 6-10 / 30 mm
Clamping range Fl / Fl (+ / II) 30 / 30 mm
Screw di M10 x 25 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 13 kA

Artikel 308026 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308026 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

For T and cross connections

Note: recommended tightening torque ≥ 10 Nm

1 Produkt

Art.-Nr. 308030 VK A R22 F40 STBL

GTIN 4013364030749, Zolltarifnr. (EU): 85359000, Bruttogewicht: 130.00 g, VPE: 50.00 db.


Abbildungen

Weitere Information

Connecting clamps for reinforcements, St/bare
Connecting clamp for connecting reinforcing steel
mesh and bar with flat conductors
For T and cross connections
Material: St/bare
Clamping range Rd / Fl: (+) 6-22 / 30-40 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 1.0 kA

Gyártó: DEHN
Típus: VK A R22 F40 STBL
Cikksz.: 308030
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Fl (+) 6-22 / 30-40 mm
Screw di M10 x 40 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 1.0 kA

Artikel 308030 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308030 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

For T, cross and parallel connections with clamping frame

For flexible connection of round conductors or for fixed earthing terminals with concomitant fixing in the formwork.

1 Produkt

Art.-Nr. 308035 VK 6.22 FL40 KB6.10 BSB STBL

GTIN 4013364123472, Zolltarifnr. (EU): 85359000, Bruttogewicht: 169.60 g, VPE: 25.00 db.


Abbildungen

Weitere Information

Connecting clamps for reinforcements, St/bare
Connecting clamp for reinforcements for connecting reinforcements to round conductors
For T, cross and parallel connections
With clamping frame for flexible connection of round conductors or fixed earthing terminals with
concomitant fixing in the formwork

Material: St/bare
Clamping range Rd / Rd: (+/II) 6-22 / 6-10 mm
Clamping range Rd / Fl: (+) 6-22 / 40 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 1.0 kA

Gyártó: DEHN
Típus: VK 6.22 FL40 KB6.10 BSB STBL
Cikksz.: 308035
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd (+/II) 6-22 / 6-10 mm
Clamping range Rd / Fl (+) 6-22 / 40 mm
Screw di M10 x 60 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 1.0 kA

Artikel 308035 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308035 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

U-bolt clamp for large diameters

1 Produkt

Art.-Nr. 308045 BVK 16.48 6.10 FL40 BSB STBL

GTIN 4013364124455, Zolltarifnr. (EU): 85359000, Bruttogewicht: 266.50 g, VPE: 25.00 db.


Abbildungen

Weitere Information

U-bolt clamp for large diameters, St/bare
U-bolt connecting clamp for reinforcements
of large diameters
For connecting reinforcements with round conductors
For cross, T and parallel connections
Material: St/bare
Clamping range Rd / Rd: (II) 16-48 / 6-10 mm
Clamping range Rd / Fl: (II) 16-48 / 30-40 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 16 kA

Gyártó: DEHN
Típus: BVK 16.48 6.10 FL40 BSB STBL
Cikksz.: 308045
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd (II) 16-48 / 6-10 mm
Clamping range Rd / Fl (II) 16-48 / 30-40 mm
Screw stirrup bolt M10 x 48 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 16 kA

Artikel 308045 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308045 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

U-bolt clamp for large diameters with two additional clamping frames

For cross connections of round conductors (6-10 mm) or for the fixing and simultaneous connection of fixed earthing terminals.

1 Produkt

Art.-Nr. 308046 BVK 16.48 FL40 KB6.10 BSB STBL

GTIN 4013364124462, Zolltarifnr. (EU): 85359000, Bruttogewicht: 292.40 g, VPE: 25.00 db.


Abbildungen

Weitere Information

U-bolt connecting clamps, St/bare
U-bolt connecting clamp for reinforcements
of large diameters
For connecting reinforcements with round conductors
For T, cross and parallel connections
With clamping frame for flexible connection of round conductors or fixed earthing terminals with
concomitant fixing in the formwork

Material: St/bare
Clamping range Rd / Rd: (+/II) 16-48 / 6-10 mm
Clamping range Rd / Fl: (II) 16-48 / 30-40 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 9.9 kA

Gyártó: DEHN
Típus: BVK 16.48 FL40 KB6.10 BSB STBL
Cikksz.: 308046
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd (+/II) 16-48 / 6-10 mm
Clamping range Rd / Fl (II) 16-48 / 30-40 mm
Screw stirrup bolt M10 x 48 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 9.9 kA

Artikel 308046 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308046 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

MAXI MV clamps

For T, cross and parallel connections.

1 Produkt

Art.-Nr. 308040 MAMVK 8.16 15.25 STBL

GTIN 4013364055902, Zolltarifnr. (EU): 85359000, Bruttogewicht: 462.30 g, VPE: 20.00 db.


Abbildungen

Weitere Information

MAXI MV clamps, St/bright
MAXI MV clamps
For connecting reinforcements to round conductors
For cross, T and parallel connections
Material: St/bare
Clamping range Rd / Rd: (+/II) 8-16 / 15-25 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 10.2 kA

Gyártó: DEHN
Típus: MAMVK 8.16 15.25 STBL
Cikksz.: 308040
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd (+/II) 8-16 / 15-25 mm
Screw di M12 x 65 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 10.2 kA
UL certification UL467B

Artikel 308040 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 308040 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

MV clamps with hexagon screw

Threaded base part.

2 Produkte

Art.-Nr. 390050 MVK 8.10 SKM10X30 STTZN

GTIN 4013364095991, Zolltarifnr. (EU): 85359000, Bruttogewicht: 101.00 g, VPE: 50.00 db.


Abbildungen

Weitere Information

MV clamp with hexagon screw, St/tZn
MV clamp
Multipurpose connecting clamp for universal use as a
cross clamp, T clamp and parallel clamp,
for round conductors
capable of carrying lightning current
tested according to EN 62561-1
with hexagon screw and threaded base part
Material: St/tZn
Clamping range Rd: 8-10 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 5.5 kA

Gyártó: DEHN
Típus: MVK 8.10 SKM10X30 STTZN
Cikksz.: 390050
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/tZn
Clamping range Rd 8-10 mm
Screw di M10 x 30 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 5.5 kA

Artikel 390050 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 390050 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 391050 MVK 10 SKM10X35 STTZN

GTIN 4013364087064, Zolltarifnr. (EU): 85359000, Bruttogewicht: 103.00 g, VPE: 50.00 db.


Abbildungen

Weitere Information

MV clamp with hexagon screw, St/tZn
MV clamp
Multipurpose connecting clamp for universal use as a
cross clamp, T clamp and parallel clamp,
for round conductors
capable of carrying lightning current
tested according to EN 62561-1
with hexagon screw and threaded base part
Material: St/tZn
Clamping range Rd: 10 mm
Standard: EN 62561-1

Gyártó: DEHN
Típus: MVK 10 SKM10X35 STTZN
Cikksz.: 391050
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/tZn
Clamping range Rd 10 mm
Screw di M10 x 35 mm
Standard EN 62561-1

Artikel 391050 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 391050 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

MV clamps with hexagon screw and spring washer

Threaded base part.

1 Produkt

Art.-Nr. 390550 MVK 8.10 SKM10X30 FSC STTZN

GTIN 4013364096042, Zolltarifnr. (EU): 85359000, Bruttogewicht: 103.00 g, VPE: 50.00 db.


Abbildungen

Weitere Information

MV clamp with hexagon screw and spring washer, St/tZn
MV clamp
Multipurpose connecting clamp for universal use as a
cross clamp, T clamp and parallel clamp,
for round conductors
capable of carrying lightning current
tested according to EN 62561-1
with hexagon screw, spring washer and threaded base part
Material: St/tZn
Clamping range Rd: 8-10 mm
Standard: EN 62561-1

Gyártó: DEHN
Típus: MVK 8.10 SKM10X30 FSC STTZN
Cikksz.: 390550
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/tZn
Clamping range Rd 8-10 mm
Screw di M10 x 30 mm
Standard EN 62561-1

Artikel 390550 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 390550 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Parallel connectors with truss head screw

2 Produkte

Art.-Nr. 306121 PV 6.22 FRM10X40 STBLANK

GTIN 4013364284920, Zolltarifnr. (EU): 85359000, Bruttogewicht: 163.16 g, VPE: 50.00 db.


Abbildungen

Weitere Information

Parallel connector with one screw, St/blank
Parallel connector for connecting two conductors in parallel arrangement
Material: St/bare
Clamping range Rd / Rd: 6-22 / 6-22 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 6.1 kA

Gyártó: DEHN
Típus: PV 6.22 FRM10X40 STBLANK
Cikksz.: 306121
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/bare
Clamping range Rd / Rd 6-22 / 6-22 mm
Screw e M10 x 40 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 6.1 kA

Artikel 306121 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 306121 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 306122 PV 6.22 FRM10X40 STTZN

GTIN 4013364284937, Zolltarifnr. (EU): 85359000, Bruttogewicht: 167.12 g, VPE: 50.00 db.


Abbildungen

Weitere Information

Parallel connector with one screw, St/tZn
Parallel connector for connecting two conductors in parallel arrangement
Material: St/tZn
Clamping range Rd / Rd: 6-22 / 6-22 mm
Standard: EN 62561-1
Short-circuit current (50 Hz): 6.1 kA

Gyártó: DEHN
Típus: PV 6.22 FRM10X40 STTZN
Cikksz.: 306122
vagy egyenértékű.

Zertifikate

 

Technische Daten

Material St/tZn
Clamping range Rd / Rd 6-22 / 6-22 mm
Screw e M10 x 40 mm
Standard EN 62561-1
Short-circuit current (50 Hz) (1 s; ≤ 300 °C) 6.1 kA

Artikel 306122 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 306122 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben