DEHNguard YPV SCI ... – compact

  • Prewired complete unit for use in photovoltaic systems
  • Combined disconnection and short-circuiting device with safe electrical isolation (patented SCI principle)
  • Tried and tested fault-resistant Y circuit of DEHNguard YPV SCI ... prevents damage to the surge protective device in case of insulation faults in the generator circuit
  • Tested to EN 50539-11
  • Suitable for use in all PV systems according to IEC 60364-7-712

Details

Three-step d.c. switching device (patented SCI principle)
lorem ipsum

DEHNguard compact YPV SCI ...

Multipole surge arrester with three-step d.c. switching device for use in PV systems

2 Produkte

Art.-Nr. 950531 DG YPV SCI 600

GTIN 4013364152953, Zolltarifnr.: 85363030, Bruttogewicht: 296.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

EHNguard compact YPV SCI 600 surge arrester
Multipole arrester for use in photovoltaic systems up to 600 V d.c.
with three-step d.c. switching device, width: 3 modules
Fault indication
Type 2 SPD according to EN 50539-11
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 600 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 2.5 kV
Short-circuit current rating Iscpv: 200 A

Brand: DEHN
Type: DG YPV SCI 600
Part No.: 950531
or equivalent.

Zertifikate

 

Technische Daten

SPD according to EN 50539-11 type 2
Max. PV voltage (UCPV ) 600 V
Short-circuit current rating (ISCPV ) 1000 A
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) 12.5 kA
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) 25 kA
Voltage protection level (UP ) ≤ 2.5 kV
Approvals KEMA, UL

Artikel 950531 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 950531 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 950530 DG YPV SCI 1000

GTIN 4013364152960, Zolltarifnr.: 85363030, Bruttogewicht: 321.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DEHNguard compact YPV SCI 1000 surge arrester
Multipole arrester for use in
photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device, width: 3 modules
Fault indication
Type 2 SPD according to EN 50539-11
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 200 A

Brand: DEHN
Type: DG YPV SCI 1000
Part No.: 950530
or equivalent.

Zertifikate

 

Technische Daten

SPD according to EN 50539-11 type 2
Max. PV voltage (UCPV ) 1000 V
Short-circuit current rating (ISCPV ) 1000 A
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) 12.5 kA
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) 25 kA
Voltage protection level (UP ) ≤ 4 kV
Approvals KEMA, UL

Artikel 950530 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 950530 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

DEHNguard compact YPV SCI ... FM

Multipole surge arrester with three-step d.c. switching device for use in PV systems, with remote signalling contact for monitoring device (floating changeover contact).

2 Produkte

Art.-Nr. 950536 DG YPV SCI 600 FM

GTIN 4013364154995, Zolltarifnr.: 85363030, Bruttogewicht: 306.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DEHNguard compact YPV SCI 600 FM surge arrester
Multipole arrester for use
in photovoltaic systems up to 600 V d.c.
with three-step d.c. switching device, width: 3 modules
with remote signalling contact
Fault indication
Type 2 SPD according to EN 50539-11
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 600 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 2.5 kV
Short-circuit current rating Iscpv: 1000 A

Brand: DEHN
Type: DG YPV SCI 600 FM
Part No.: 950536
or equivalent.

Zertifikate

 

Technische Daten

SPD according to EN 50539-11 type 2
Max. PV voltage (UCPV ) 600 V
Short-circuit current rating (ISCPV ) 1000 A
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) 12.5 kA
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) 25 kA
Voltage protection level (UP ) ≤ 2.5 kV
Approvals KEMA, UL
Type of remote signalling contact changeover contact

Artikel 950536 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 950536 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 950535 DG YPV SCI 1000 FM

GTIN 4013364154988, Zolltarifnr.: 85363030, Bruttogewicht: 331.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

DEHNguard compact YPV SCI 1000 FM surge arrester
Multipole arrester for use in
photovoltaic systems up to 1000 V d.c.
with three-step d.c. switching device, width: 3 modules
Fault indication with remote signalling contact
Type 2 SPD according to EN 50539-11
For use in accordance with IEC 60364-7-712
Safe electrical isolation in the protection module
Max. PV voltage: <= 1000 V d.c.
Total discharge current: 40 kA
Voltage protection level: <= 4 kV
Short-circuit current rating Iscpv: 1000 A

Brand: DEHN
Type: DG YPV SCI 1000 FM
Part No.: 950535
or equivalent.

Zertifikate

 

Technische Daten

SPD according to EN 50539-11 type 2
Max. PV voltage (UCPV ) 1000 V
Short-circuit current rating (ISCPV ) 1000 A
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) 12.5 kA
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) 25 kA
Voltage protection level (UP ) ≤ 4 kV
Approvals KEMA, UL
Type of remote signalling contact changeover contact

Artikel 950535 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 950535 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben

Cookie-Einstellungen

Wir verwenden Cookies, um Ihnen ein optimales Webseiten-Erlebnis zu bieten. Dazu zählen Cookies, die für den Betrieb der Seite und für die Steuerung unserer kommerziellen Unternehmensziele notwendig sind, sowie solche, die lediglich zu anonymen Statistikzwecken, für Komforteinstellungen oder zur Anzeige personalisierter Inhalte genutzt werden. Sie können selbst entscheiden, welche Kategorien Sie zulassen möchten. Bitte beachten Sie, dass auf Basis Ihrer Einstellungen womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen. Weitere Informationen finden Sie in unseren Datenschutzerklärung.
Wenn Sie in die Nutzung von Cookies eingewilligt haben, können Sie dies jederzeit nach Klick auf den Link "Cookie-Einstellungen ändern" im Footer der Seite widerrufen.

  • Details anzeigen Details ausblenden
    Notwendig

    Diese Cookies sind für den Betrieb der Seite unbedingt notwendig und ermöglichen beispielsweise sicherheitsrelevante Funktionalitäten. Außerdem können wir mit dieser Art von Cookies ebenfalls erkennen, ob Sie in Ihrem Profil eingeloggt bleiben möchten, um Ihnen unsere Dienste bei einem erneuten Besuch unserer Seite schneller zur Verfügung zu stellen.

    Statistik & Marketing

    Um unser Angebot und unsere Webseite weiter zu verbessern, erfassen wir anonymisierte Daten für Statistiken und Analysen. Mithilfe dieser Cookies können wir beispielsweise die Besucherzahlen und den Effekt bestimmter Seiten unseres Web-Auftritts ermitteln und unsere Inhalte optimieren.