Insulating Enclosures

Lightning-impulse-current-tested insulating enclosure for arresters

IGA 10 V2 IP54

Lightning-current-tested insulating enclosure with a max. capacity of ten modules; with grommet flange for 11 EPDM cables (Ø5-30 mm) and three mounted M20 grommet openings with lock nut; ideally suited for series connection.

1 Produkt

Art.-Nr. 902315 IGA 10 V2 IP54

GTIN 4013364125759, Zolltarifnr.: 85389099, Bruttogewicht: 1.83 kg, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

IGA 10 V2 IP54 enclosure, 10 modules
Enclosure for installing surge arresters tested
with lightning impulse currents
Degree of protection: IP 54
Type of cover: transparent cover
Number of cable entries: 1 x for cables Ø7...10 mm;
2x for cables Ø10...14 mm or Ø15...30 mm each;
3 x for cables Ø8...13 mm
Sealable
Colour of the enclosure: grey
Dimensions: 200 x 300 x 132 mm
Installation space: 10 modules, DIN 43880

Brand: DEHN
Type: IGA 10 V2 IP54
Part No.: 902315
or equivalent.

 

Technische Daten

Degree of protection IP 54
Type lightning-current-tested
Number of cable entries 4x for cables Ø5-7mm; 3x for cables Ø7-10 mm; 2x for cables Ø10-14 mm or Ø15-30 mm each; 3x for cables Ø8-13 mm
Capacity 10 modules, DIN 43880
Dimensions (W x H x D ) 200 x 300 x 132 mm
Cover sealable

Artikel 902315 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 902315 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

IGA 7 IP54

Lightning-current-tested insulating enclosure with a max. capacity of seven modules; with EPDM grommet flange for two cables (Ø1-25 mm) and three mounted M20 grommet openings with lock nut; ideally suited for series connection.

1 Produkt

Art.-Nr. 902314 IGA 7 IP54

GTIN 4013364151031, Zolltarifnr.: 85389099, Bruttogewicht: 786.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

IGA 7 IP54 enclosure, 7 modules
Enclosure for installing surge arresters tested
with lightning impulse currents
Degree of protection: IP 54
Type of cover: transparent cover
Number of cable entries: 2 x for cables Ø1...25 mm;
3 x for cables Ø8...13 mm
Sealable
Colour of the enclosure: grey
Dimensions: 175 x 250 x 100 mm
Installation space: 7 modules, DIN 43880

Brand: DEHN
Type: IGA 7 IP54
Part No.: 902314
or equivalent.

Zertifikate

 

Technische Daten

Degree of protection IP 54
Type lightning-current-tested
Number of cable entries 2x for cables Ø1-25 mm; 3x for cables Ø8-13 mm
Capacity 7 modules, DIN 43880
Dimensions (W x H x D ) 175 x 250 x 100 mm
Cover sealable

Artikel 902314 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 902314 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

IGA 6 IP54

Lightning-current-tested insulating enclosure with a max. capacity of six modules for non-exhausting arresters; with knockouts for entering the cables and plug-in glands; ideally suited for series connection.

1 Produkt

Art.-Nr. 902485 IGA 6 IP54

GTIN 4013364045767, Zolltarifnr.: 85381000, Bruttogewicht: 723.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

IGA 6 IP54 enclosure, 6 modules
Enclosure for installation of non-exhausting arresters
Degree of protection IP 54
With transparent cover,
sealable, with 2 plug-in-glands EST 21,
for cables durchschnittlich 9...21 mm,
Colour of enclosure grey
Dimension: 165 x 255 x 111
mm
Available installation space: 6 mods., DIN 43880

Brand: DEHN
Type: IGA 6 IP54
Part No.: 902485
or equivalent.

 

Technische Daten

Degree of protection IP 54
Type lightning-current-tested
Number of cable entries 2 plug-in glands for cables Ø8-23 mm (M32 knockout)
Capacity 6 modules, DIN 43880
Dimensions (W x H x D ) 165 x 255 x 115 mm
Cover sealable

Artikel 902485 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 902485 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

IGA 12 IP54

Insulating enclosure with a max. capacity of 12 modules for non-exhausting arresters; with integrated elastic sealing grommet for entering the cables; ideally suited for series connection.

1 Produkt

Art.-Nr. 902471 IGA 12 IP54

GTIN 4013364108943, Zolltarifnr.: 85381000, Bruttogewicht: 2.01 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

IGA 12 IP54 enclosure, 12modules
with PE and N plug-in terminals
Enclosure for installing surge arresters tested
with lightning impulse currents
Degree of protection: IP 54
Type of cover: transparent cover
integrated elastic seal membrane
PE/N Quantity x Cross section: 3 x 25 mm², 12 x 4
mm², Cu
Sealable
Colour of the enclosure: grey
Dimensions: 295 x 333 x 129 mm
Installation space: 12 modules, DIN 43880

Brand: DEHN
Type: IGA 12 IP54
Part No.: 902471
or equivalent.

 

Technische Daten

Degree of protection IP 54
Number of cable entries 8x for cables Ø7-12 mm; 8x for cables Ø7-14 mm; 4x for cables Ø12-20 mm; 1x for cables Ø16.5-29 mm (top and bottom)
PE / N quantity x cross-section 3x 25 mm2, 12x 4 mm2, Cu
Capacity 12 modules, DIN 43880
Dimensions (W x H x D ) 295 x 333 x 129 mm

Artikel 902471 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 902471 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

IGA 12 IP65

Lightning-current-tested insulating enclosure with a max. capacity of 12 modules for non-exhausting arresters; with integrated elastic sealing grommet for entering the cables; ideally suited for series connection.

1 Produkt

Art.-Nr. 902316 IGA 12 IP65

GTIN 4013364151048, Zolltarifnr.: 85389099, Bruttogewicht: 1.92 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

IGA 12 IP65 enclosure, 12 modules
with PE and N plug-in terminals
Installing enclosure for non-exhausting surge
Degree of protection: IP 65
Type of cover: transparent cover
integrated elastic seal membrane
PE/N Quantity x Cross section: 3 x 25 mm², 12 x 4
mm², Cu
Colour of the enclosure: grey
Dimensions: 295 x 333 x 129 mm
Installation space: 12 modules, DIN 43880

Brand: DEHN
Type: IGA 12 IP65
Part No.: 902316
or equivalent.

 

Technische Daten

Degree of protection IP 65
Type lightning-current-tested
Number of cable entries 8x for cables Ø7-12 mm; 8x for cables Ø7-14 mm; 4x for cables Ø12-20 mm; 1x for cables Ø16.5-29 mm (top and bottom)
PE / N quantity x cross-section 3x 25 mm2, 12x 4 mm2, Cu
Capacity 12 modules, DIN 43880
Dimensions (W x H x D ) 295 x 333 x 129 mm

Artikel 902316 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 902316 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

IGA 24 IP54

Insulating enclosure with a max. capacity of 2x 12 modules for non-exhausting arresters; with integrated elastic sealing grommet for entering the cables; ideally suited for series connection.

1 Produkt

Art.-Nr. 902472 IGA 24 IP54

GTIN 4013364108950, Zolltarifnr.: 85381000, Bruttogewicht: 2.61 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

IGA 24 IP54 enclosure, 2X12 modules
with PE and N plug-in terminals
Enclosure for arresters without venting means
Degree of protection: IP54
Type of cover: transparent door
Integrated elastic seal membrane for entering
cables
PE/N quantity x cross section: 6 x 25 mm², 24 x 4 mm², Cu
Colour of enclosure: grey
Dimensions: 295 x 458 x 129 mm
Capacity: (2 x 12) mods., DIN 3880

Brand: DEHN
Type: IGA 24 IP54
Part No.: 902472
or equivalent.

 

Technische Daten

Degree of protection IP 54
Number of cable entries 8x for cables Ø7-12 mm; 8x for cables Ø7-14 mm; 4x for cables Ø12-20 mm; 1x for cables Ø16.5-29 mm (top and bottom)
PE / N quantity x cross-section 6x 25 mm2, 24x 4 mm2, Cu
Capacity 24 modules (2x 12 modules), DIN 43880
Dimensions (W x H x D ) 295 x 458 x 129 mm

Artikel 902472 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 902472 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben

Cookie-Einstellungen

Wir verwenden Cookies, um Ihnen ein optimales Webseiten-Erlebnis zu bieten. Dazu zählen Cookies, die für den Betrieb der Seite und für die Steuerung unserer kommerziellen Unternehmensziele notwendig sind, sowie solche, die lediglich zu anonymen Statistikzwecken, für Komforteinstellungen oder zur Anzeige personalisierter Inhalte genutzt werden. Sie können selbst entscheiden, welche Kategorien Sie zulassen möchten. Bitte beachten Sie, dass auf Basis Ihrer Einstellungen womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen. Weitere Informationen finden Sie in unseren Datenschutzerklärung.
Wenn Sie in die Nutzung von Cookies eingewilligt haben, können Sie dies jederzeit nach Klick auf den Link "Cookie-Einstellungen ändern" im Footer der Seite widerrufen.

  • Details anzeigen Details ausblenden
    Notwendig

    Diese Cookies sind für den Betrieb der Seite unbedingt notwendig und ermöglichen beispielsweise sicherheitsrelevante Funktionalitäten. Außerdem können wir mit dieser Art von Cookies ebenfalls erkennen, ob Sie in Ihrem Profil eingeloggt bleiben möchten, um Ihnen unsere Dienste bei einem erneuten Besuch unserer Seite schneller zur Verfügung zu stellen.

    Statistik & Marketing

    Um unser Angebot und unsere Webseite weiter zu verbessern, erfassen wir anonymisierte Daten für Statistiken und Analysen. Mithilfe dieser Cookies können wir beispielsweise die Besucherzahlen und den Effekt bestimmter Seiten unseres Web-Auftritts ermitteln und unsere Inhalte optimieren.