Art.-Nr. 908300 DG MU 3PY 208 3W+G
GTIN 4013364148680, Zolltarifnr.: 85363030, Bruttogewicht: 323.70 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 180 V a.c. / 360 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 600 Vpk / 1200 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908314 DG MU 3PY 480 3W+G
GTIN 4013364148703, Zolltarifnr.: 85363030, Bruttogewicht: 360.30 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 385 V a.c. / 770 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1200 Vpk / 2500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908301 DG MU 3PY 600 3W+G
GTIN 4013364148727, Zolltarifnr.: 85363030, Bruttogewicht: 383.70 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 510 V a.c. / 1020 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1500 Vpk / 3000 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908305 DG MU 3PY 208 3W+G R
GTIN 4013364148697, Zolltarifnr.: 85363030, Bruttogewicht: 330.90 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 180 V a.c. / 360 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 600 Vpk / 1200 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908319 DG MU 3PY 480 3W+G R
GTIN 4013364148710, Zolltarifnr.: 85363030, Bruttogewicht: 368.10 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 385 V a.c. / 770 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1200 Vpk / 2500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908306 DG MU 3PY 600 3W+G R
GTIN 4013364148734, Zolltarifnr.: 85363030, Bruttogewicht: 391.20 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 510 V a.c. / 1020 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1500 Vpk / 3000 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908350 DG MU 3PD 480 3W+G
GTIN 4013364148741, Zolltarifnr.: 85363030, Bruttogewicht: 393.70 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 550 V a.c. / 1100 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1800 Vpk / 3000 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908351 DG MU 3PD 240 3W+G
GTIN 4013364148826, Zolltarifnr.: 85363030, Bruttogewicht: 339.90 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 275 V a.c. / 550 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 800 Vpk / 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908355 DG MU 3PD 480 3W+G R
GTIN 4013364148758, Zolltarifnr.: 85363030, Bruttogewicht: 400.50 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 550 V a.c. / 1100 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1800 Vpk / 3000 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908356 DG MU 3PD 240 3W+G R
GTIN 4013364148833, Zolltarifnr.: 85363030, Bruttogewicht: 346.30 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 275 V a.c. / 550 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 800 Vpk / 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908340 DG MU 3PY 208 4W+G
GTIN 4013364148840, Zolltarifnr.: 85363030, Bruttogewicht: 412.30 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 180 V a.c. / 360 V a.c. / 360 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 600 Vpk / 1200 Vpk / 1200 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908341 DG MU 3PY 480 4W+G
GTIN 4013364148864, Zolltarifnr.: 85363030, Bruttogewicht: 449.40 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 385 V a.c. / 565 V a.c. / 770 V a.c./ 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 1200 Vpk / 1800 Vpk / 2500 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908342 DG MU 3PY 600 4W+G
GTIN 4013364148765, Zolltarifnr.: 85363030, Bruttogewicht: 473.60 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 510 V a.c. / 690 V a.c. / 1020 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 1500 Vpk / 2000 Vpk / 3000 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908345 DG MU 3PY 208 4W+G R
GTIN 4013364148857, Zolltarifnr.: 85363030, Bruttogewicht: 419.50 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 180 V a.c. / 360 V a.c. / 360 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 600 Vpk / 1200 Vpk / 1200 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908346 DG MU 3PY 480 4W+G R
GTIN 4013364148871, Zolltarifnr.: 85363030, Bruttogewicht: 458.30 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 385 V a.c. / 565 V a.c. / 770 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 1200 Vpk / 1800 Vpk / 2500 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908347 DG MU 3PY 600 4W+G R
GTIN 4013364148772, Zolltarifnr.: 85363030, Bruttogewicht: 481.50 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 510V a.c. / 690 V a.c. / 1020 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 1500 Vpk / 2000pk V / 3000pk V / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908343 DG MU 3PH 240 4W+G
GTIN 4013364148789, Zolltarifnr.: 85363030, Bruttogewicht: 424.80 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] | 230 V a.c. / 275 V a.c. / 410 V a.c. / 455 V a.c. / 460 V a.c. / 505 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] (VPR) | 700 Vpk / 800 Vpk / 1200 Vpk / 1500 Vpk / 1500 Vpk / 1500 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908344 DG MU 3PH 480 4W+G
GTIN 4013364148802, Zolltarifnr.: 85363030, Bruttogewicht: 456.50 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] | 385V a.c. / 510 V a.c. / 565 V a.c. / 690 V a.c. / 770 V a.c. / 895 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] (VPR) | 1200 Vpk / 1500 Vpk / 1800 Vpk / 2000 Vpk / 2500 Vpk / 2500 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908348 DG MU 3PH 240 4W+G R
GTIN 4013364148796, Zolltarifnr.: 85363030, Bruttogewicht: 432.50 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] | 230 V a.c. / 275 V a.c. / 410 V a.c. / 455 V a.c. / 460 V a.c. / 505 V a.c. / 180V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] (VPR) | 700 Vpk / 800 Vpk / 1200 Vpk / 1500 Vpk / 1500 Vpk / 1500 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908349 DG MU 3PH 480 4W+G R
GTIN 4013364148819, Zolltarifnr.: 85363030, Bruttogewicht: 464.40 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] | 385 V a.c. / 510 V a.c. / 565 V a.c. / 690 V a.c. / 770 V a.c. / 895 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [H-N] / [L-G] / [H-G] / [L-L] / [L-H] / [N-G] (VPR) | 1200 Vpk / 1500 Vpk / 1800 Vpk / 2000 Vpk / 2500 Vpk / 2500 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908190 DG MU SP 240 3W+G
GTIN 4013364148604, Zolltarifnr.: 85363030, Bruttogewicht: 235.10 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 230 V a.c. / 460 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 700 Vpk / 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908192 DG MU SP 480 3W+G
GTIN 4013364148628, Zolltarifnr.: 85363030, Bruttogewicht: 254.10 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 385 V a.c. / 770 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1200 Vpk / 2500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908195 DG MU SP 240 3W+G R
GTIN 4013364148611, Zolltarifnr.: 85363030, Bruttogewicht: 241.00 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 230 V a.c. / 460 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 700 Vpk / 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908197 DG MU SP 480 3W+G R
GTIN 4013364148635, Zolltarifnr.: 85363030, Bruttogewicht: 259.30 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 385 V a.c. / 770 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1200 Vpk / 2500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908214 DG MU SPN 240 3W+G
GTIN 4013364267961, Zolltarifnr.: 85363030, Bruttogewicht: 331.00 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 180 V a.c. / 360 V a.c. / 360 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 600 Vpk / 1200 Vpk / 1200 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908219 DG MU SPN 240 3W+G R
GTIN 4013364267978, Zolltarifnr.: 85363030, Bruttogewicht: 338.00 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-N] / [L-G] / [L-L] / [N-G] (MCOV) | 180 V a.c. / 360 V a.c. / 360 V a.c. / 180 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-N] / [L-G] / [L-L] / [N-G] (VPR) | 600 Vpk / 1200 Vpk / 1200 Vpk / 600 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908203 DG MU CGD 240 3W+G
GTIN 4013364148642, Zolltarifnr.: 85363030, Bruttogewicht: 240.80 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 275 V a.c. / 550 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 800 Vpk / 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908204 DG MU CGD 480 3W+G
GTIN 4013364148666, Zolltarifnr.: 85363030, Bruttogewicht: 275.10 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 550 V a.c. / 1100 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1800 Vpk / 3000 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908208 DG MU CGD 240 3W+G R
GTIN 4013364148659, Zolltarifnr.: 85363030, Bruttogewicht: 246.40 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 275 V a.c. / 550 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 800 Vpk / 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908209 DG MU CGD 480 3W+G R
GTIN 4013364148673, Zolltarifnr.: 85363030, Bruttogewicht: 282.00 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC [L-G] / [L-L] (MCOV) | 550 V a.c. / 1100 V a.c. |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating [L-G] / [L-L] (VPR) | 1800 V / 3000 V |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908070 DG SU 1P 120
GTIN 4013364148499, Zolltarifnr.: 85363030, Bruttogewicht: 123.80 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC (MCOV) | 230 Vac |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating (VPR) | 700 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908074 DG SU 1P 240
GTIN 4013364148567, Zolltarifnr.: 85363030, Bruttogewicht: 133.30 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC (MCOV) | 385 Vac |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating (VPR) | 1200 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908076 DG SU 1P 347
GTIN 4013364148581, Zolltarifnr.: 85363030, Bruttogewicht: 140.80 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC (MCOV) | 510 Vac |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating (VPR) | 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908090 DG SU 1P 120 R
GTIN 4013364148550, Zolltarifnr.: 85363030, Bruttogewicht: 127.70 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC (MCOV) | 230 Vac |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating (VPR) | 700 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908094 DG SU 1P 240 R
GTIN 4013364148574, Zolltarifnr.: 85363030, Bruttogewicht: 136.60 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC (MCOV) | 385 Vac |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating (VPR) | 1200 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |
Art.-Nr. 908096 DG SU 1P 347 R
GTIN 4013364148598, Zolltarifnr.: 85363030, Bruttogewicht: 144.60 g, VPE: 1.00 pc(s)
Technische Daten
SPD as per ANSI/UL 1449 | Open-Type 1 SPD |
SPD as per CSA-C22.2 no. 269.1 | Type 4-1 Component Assembly |
Max. continuous operating voltage AC (MCOV) | 510 Vac |
Nominal discharge current (8x 20 µs) (In ) | 20 kA |
Voltage protection rating (VPR) | 1500 Vpk |
Max. mains-side overcurrent protection | Not needed |
Approvals | UL, CSA |
Remote status contact | Floating (dry), Form C (SPDT) |
Extended technical data: | --------------------------------- |
Max. discharge current (8/20) (Imax ) | 50 kA |