EXFS L / EXFS KU

  • For indirect connection / earthing of functionally isolated parts of installations under lightning conditions
  • For lightning equipotential bonding according to IEC 62305 in hazardous areas (zone 2)
  • Corrosion-resistant zinc die-cast enclosure with plastic cover and flexible cable connection
  • For bridging insulating joints, insulating flanges etc. in cathodically protected pipe sections
  • Extremely heavy-duty device
  • Approval according to ATEX directive 94/9/EC and IECEx

Details

lorem ipsum
lorem ipsum

EXFS L

Ex isolating spark gap for aboveground installation.

3 Produkte

Art.-Nr. 923060 EXFS L100

GTIN 4013364038899, Zolltarifnr.: 85369095, Bruttogewicht: 805.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

Ex isolating spak gap of type EXFS L100
Ex isolating spak gap of type EXFS L100
for hazardous areas (zone 2) with flexible connecting cable, ATEX-certified (94/9/EC),
for lightning equipotential bonding according to IEC 62305-4
Lightning impulse current (10/350): 50 kA
Class of lightning current carrying capability acc. to EN 50164-3: N
Nominal discharge current (8/20): 100 kA
100% lightning impulse sparkover voltage: <= 2.5 kV
Power frequency sparkover voltage (50Hz): <= 1.2 kV
Cable length: 100 mm
For flange size: 20 - 130 mm

Brand: DEHN
Type: EXFS L100
Part No.: 923060
or equivalent.

Zertifikate

 

Technische Daten

Isolating spark gap according to EN 62561-3 / IEC 62561-3 yes
Lightning impulse current (10/350 µs) (Iimp ) 50 kA
Class (lightning current carrying capability) N
Rated impulse sparkover voltage (Ur imp ) ≤ 2.5 kV
Degree of protection IP 54
ATEX approvals DEKRA 11ATEX0146 X
Ex marking according to EN 60079-0 and EN 60079-15: gas II 3 G Ex nC IIC T4 Gc
IECEx approvals IECEx DEK 11.0063X
Ex marking according to EN 60079-0 Ex nC IIC T4 Gc
Cable length 100 mm

Artikel 923060 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 923060 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 923061 EXFS L200

GTIN 4013364038905, Zolltarifnr.: 85369095, Bruttogewicht: 830.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

Ex isolating spark gap of type EXFS L200
Ex isolating spak gap of type EXFS L200
for hazardous areas (zone 2) with flexible connecting cable, ATEX-certified (94/9/EC),
for lightning equipotential bonding according to IEC 62305-4
Lightning impulse current (10/350): 50 kA
Class of lightning current carrying capability acc. to EN 50164-3: N
Nominal discharge current (8/20): 100 kA
100% lightning impulse sparkover voltage: <= 2.5 kV
Power frequency sparkover voltage (50Hz): <= 1.2 kV
Cable length: 200 mm
For flange size: 120 - 230 mm

Brand: DEHN
Type: EXFS L200
Part No.: 923061
or equivalent.

Zertifikate

 

Technische Daten

Isolating spark gap according to EN 62561-3 / IEC 62561-3 yes
Lightning impulse current (10/350 µs) (Iimp ) 50 kA
Class (lightning current carrying capability) N
Rated impulse sparkover voltage (Ur imp ) ≤ 2.5 kV
Degree of protection IP 54
ATEX approvals DEKRA 11ATEX0146 X
Ex marking according to EN 60079-0 and EN 60079-15: gas II 3 G Ex nC IIC T4 Gc
IECEx approvals IECEx DEK 11.0063X
Ex marking according to EN 60079-0 Ex nC IIC T4 Gc
Cable length 200 mm

Artikel 923061 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 923061 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 923062 EXFS L300

GTIN 4013364038912, Zolltarifnr.: 85369095, Bruttogewicht: 813.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

Ex isolating spark gap of type EXFS L300
Ex isolating spak gap of type EXFS L300
for hazardous areas (zone 2) with flexible connecting cable, ATEX-certified (94/9/EC),
for lightning equipotential bonding according to IEC 62305-4
Lightning impulse current (10/350): 50 kA
Class of lightning current carrying capability acc. to EN 50164-3: N
Nominal discharge current (8/20): 100 kA
100% lightning impulse sparkover voltage: <= 2.5 kV
Power frequency sparkover voltage (50Hz): <= 1.2 kV
Cable length: 300 mm
For flange size: 220 - 320 mm

Brand: DEHN
Type: EXFS L300
Part No.: 923062
or equivalent.

Zertifikate

 

Technische Daten

Isolating spark gap according to EN 62561-3 / IEC 62561-3 yes
Lightning impulse current (10/350 µs) (Iimp ) 50 kA
Class (lightning current carrying capability) N
Rated impulse sparkover voltage (Ur imp ) ≤ 2.5 kV
Degree of protection IP 54
ATEX approvals DEKRA 11ATEX0146 X
Ex marking according to EN 60079-0 and EN 60079-15: gas II 3 G Ex nC IIC T4 Gc
IECEx approvals IECEx DEK 11.0063X
Ex marking according to EN 60079-0 Ex nC IIC T4 Gc
Cable length 300 mm

Artikel 923062 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 923062 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

EXFS KU

Ex isolating spark gap with connecting cables for aboveground and underground installation; with water-proof sheath; can be shortened for short cable lengths.

1 Produkt

Art.-Nr. 923019 EXFS KU

GTIN 4013364033177, Zolltarifnr.: 85369095, Bruttogewicht: 1.72 kg, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

Ex isolating spark gap of type EXFS KU
Ex isolating spark gap of type EXFS KU for hazardous areas (zone 2)
with connecting cables for aboveground and underground installation
ATEX-certified (94/9/EC)
For lightning equipotential bonding according to IEC 62305-4
Lightning impulse current (10/350): 50 kA
Class of lightning current carrying capability acc. to EN 50164-3: N
Nominal discharge current (8/20): 100 kA
100% lightning impulse sparkover voltage: <= 2.5 kV
Power frequency sparkover voltage (50Hz): <= 1.2 kV
Cable length: 2x approx. 1500 mm

Brand: DEHN
Type: EXFS KU
Part No.: 923019
or equivalent.

Zertifikate

 

Technische Daten

Isolating spark gap according to EN 62561-3 / IEC 62561-3 yes
Lightning impulse current (10/350 µs) (Iimp ) 50 kA
Class (lightning current carrying capability) N
Rated impulse sparkover voltage (Ur imp ) ≤ 2.5 kV
Degree of protection IP 67
ATEX approvals DEKRA 11ATEX0146 X
Ex marking according to EN 60079-0 and EN 60079-15: gas II 3 G Ex nC IIC T4 Gc
IECEx approvals IECEx DEK 11.0063X
Ex marking according to EN 60079-0 Ex nC IIC T4 Gc
Cable length 2x approx. 1500 mm

Artikel 923019 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 923019 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben

Cookie-Einstellungen

Wir verwenden Cookies, um Ihnen ein optimales Webseiten-Erlebnis zu bieten. Dazu zählen Cookies, die für den Betrieb der Seite und für die Steuerung unserer kommerziellen Unternehmensziele notwendig sind, sowie solche, die lediglich zu anonymen Statistikzwecken, für Komforteinstellungen oder zur Anzeige personalisierter Inhalte genutzt werden. Sie können selbst entscheiden, welche Kategorien Sie zulassen möchten. Bitte beachten Sie, dass auf Basis Ihrer Einstellungen womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen. Weitere Informationen finden Sie in unseren Datenschutzerklärung.
Wenn Sie in die Nutzung von Cookies eingewilligt haben, können Sie dies jederzeit nach Klick auf den Link "Cookie-Einstellungen ändern" im Footer der Seite widerrufen.

  • Details anzeigen Details ausblenden
    Notwendig

    Diese Cookies sind für den Betrieb der Seite unbedingt notwendig und ermöglichen beispielsweise sicherheitsrelevante Funktionalitäten. Außerdem können wir mit dieser Art von Cookies ebenfalls erkennen, ob Sie in Ihrem Profil eingeloggt bleiben möchten, um Ihnen unsere Dienste bei einem erneuten Besuch unserer Seite schneller zur Verfügung zu stellen.

    Statistik & Marketing

    Um unser Angebot und unsere Webseite weiter zu verbessern, erfassen wir anonymisierte Daten für Statistiken und Analysen. Mithilfe dieser Cookies können wir beispielsweise die Besucherzahlen und den Effekt bestimmter Seiten unseres Web-Auftritts ermitteln und unsere Inhalte optimieren.