Shield Connection for Cables
- Lightning-impulse-current-tested up to 10 kA (10/350 µs)
- Extremely space-saving
- Spring element ensures permanent shield connection
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919031
SA KRF 10 V2A
€8.30
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919032
SA KRF 15 V2A
€10.80
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919033
SA KRF 22 V2A
€17.20
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919034
SA KRF 29 V2A
€20.30
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919035
SA KRF 37 V2A
€24.20
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919036
SA KRF 50 V2A
€27.90
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919037
SA KRF 70 V2A
€35.80
list price per item
item
Constant Force Spring
Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation.
Part No. 919038
SA KRF 94 V2A
€51.60
list price per item
item
Self-bonding Rubber Tape
Roll with 9 m self-bonding rubber tape for wrapping around constant force springs for permanent corrosion protection.
Part No. 919030
SKB 19 9M SW
€69.90
list price per item
item