BLITZDUCTORconnect – Compact
Universal lightning current and surge arrester
Compact arrester
Function-optimised design with a width of 6 mm
- For protecting data bus interfaces as well as measuring and control circuits
- High discharge capacity of 3 kA (10/350 µs), 10 kA (8/20 µs)
- Max. impulse current carrying capability (8/20 µs) Imax up to 20 kA
- Low voltage protection level, also capable of protecting terminal equipment
Compact arrester
- Fast and simple cable connection thanks to push-in connection technology
- High system availability thanks to fail-safe performance
Function-optimised design with a width of 6 mm
- LifeCheck and visual status indication integrated in the module
- Simple remote signalling of the status with the help of an optional remote signalling unit
- Vibration and shock-tested for safe operation
15 Products
BCO CL2 B 180
Space-saving, compact lightning current arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines for lightning equipotential bonding as well as indirect earthing of shielded cables.
Part No. 927910
BCO CL2 B 180
€63.20
list price per item
item
BCO CL2 BE
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927922
BCO CL2 BE 12
€117.60
list price per item
item
BCO CL2 BE
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927924
BCO CL2 BE 24
€117.60
list price per item
item
BCO CL2 BE
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927925
BCO CL2 BE 48
€117.60
list price per item
item
BCO CL2 BD
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces.
Part No. 927942
BCO CL2 BD 12
€117.60
list price per item
item
BCO CL2 BD
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces.
Part No. 927944
BCO CL2 BD 24
€117.60
list price per item
item
BCO CL2 BD
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces.
Part No. 927945
BCO CL2 BD 48
€117.60
list price per item
item
BCO CL2 BE HF
Space-saving, combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines of high-frequency transmissions sharing a common reference potential as well as unbalanced interfaces.
Part No. 927970
BCO CL2 BE HF 5
€136.50
list price per item
item
BCO CL2 BD HF
Space-saving, compact combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed high-frequency bus systems as well as balanced interfaces.
Part No. 927971
BCO CL2 BD HF 5
€136.50
list price per item
item
BCO CL2 E
Space-saving, compact surge arrester with a width of 6 mm and push-in connection technology with status indication. Finely limiting, single-stage surge protection with powerful diodes for protecting two single cores sharing a common reference potential as well as unbalanced interfaces.
Part No. 927987
BCO CL2 E 12
€66.60
list price per item
item
BCO CL2 E
Space-saving, compact surge arrester with a width of 6 mm and push-in connection technology with status indication. Finely limiting, single-stage surge protection with powerful diodes for protecting two single cores sharing a common reference potential as well as unbalanced interfaces.
Part No. 927988
BCO CL2 E 24
€66.60
list price per item
item
BCO CL2 E
Space-saving, compact surge arrester with a width of 6 mm and push-in connection technology with status indication. Finely limiting, single-stage surge protection with powerful diodes for protecting two single cores sharing a common reference potential as well as unbalanced interfaces.
Part No. 927989
BCO CL2 E 48
€66.60
list price per item
item
BCO CL4 BC
Space-saving, compact combined arrester with a width of 12 mm and push-in connection technology with status indication for protecting unearthed 4-conductor measuring circuits for IT systems and measuring and control systems.
Part No. 927954
BCO CL4 BC 24
€170.30
list price per item
item
BCO CL2 BD HC10A 24
Space-saving, compact combined arrester with a width of 12 mm and push-in connection technology with status indication for protecting one pair in unearthed DC supplies for IT systems and measuring and control circuits.
Part No. 927408
BCO CL2 BD HC10A 24
€206.90
list price per item
item
BCO CL2 BD EX 24
Space-saving, compact surge arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of intrinsically safe measuring circuits and bus systems, meets FISCO requirements. Insulation strength > 500 V line-ground.
Part No. 927984
BCO CL2 BD EX 24
€134.00
list price per item
item