BLITZDUCTORconnect – Modular

Lightning current and surge arrester for universal use
  • protecting measuring and control circuits, bus and telecommunication systems
  • High total discharge capacity of 3 kA (10/350 µs), 10 kA (8/20 µs)
  • Max. impulse current carrying capability (8/20 µs) Imax up to 20 kA
  • Low voltage protection level, also capable of protecting terminal equipment

Arrester separable into module and base part
  • Fast and simple conductor connection thanks to push-in connection terminals
  • All protection components integrated in the module
  • secR release buttons on both sides for safe module replacement
  • High system availability thanks to fail-safe performance

Function-optimised design with a width of 6 mm
  • LifeCheck and visual status indication integrated in the module
  • Simple remote signalling of the status with the help of an optional remote signalling unit
  • Tool-free signal circuit disconnection for maintenance purposes
  • Vibration and shock-tested for safe operation

37 Products

BCO ML2 B 180

Space-saving, modular lightning current arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines for lightning equipotential bonding as well as indirect earthing of shielded cables. With signal disconnection for maintenance purposes.
Part No. 927210
BCO ML2 B 180

€119.30

list price per item

item

BCO ML2 BE

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927222
BCO ML2 BE 12

€183.80

list price per item

item

BCO ML2 BE

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927224
BCO ML2 BE 24

€183.80

list price per item

item

BCO ML2 BE

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927225
BCO ML2 BE 48

€183.80

list price per item

item

BCO ML2 BE

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927227
BCO ML2 BE 180

€183.80

list price per item

item

BCO ML2 BD

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927242
BCO ML2 BD 12

€183.80

list price per item

item

BCO ML2 BD

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces. With signal disconnection for maintenance purposes.

Part No. 927244
BCO ML2 BD 24

€183.80

list price per item

item

BCO ML2 BD

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927245
BCO ML2 BD 48

€183.80

list price per item

item

BCO ML2 BD

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed balanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927247
BCO ML2 BD 180

€183.80

list price per item

item

BCO ML2 BE HF

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines of high-frequency transmissions sharing a common reference potential as well as unbalanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927270
BCO ML2 BE HF 5

€198.60

list price per item

item

BCO ML2 BE HF

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting two single lines of high-frequency transmissions sharing a common reference potential as well as unbalanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927274
BCO ML2 BE HF 24

€198.60

list price per item

item

BCO ML2 BD HF

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed high-frequency bus systems as well as balanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927271
BCO ML2 BD HF 5

€198.60

list price per item

item

BCO ML2 BD HF

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of unearthed high-frequency bus systems as well as balanced interfaces. With signal disconnection for maintenance purposes.
Part No. 927275
BCO ML2 BD HF 24

€198.60

list price per item

item

BCO ML2 BD HC5A 24

Space-saving, modular combined arrester with a width of 6 mm and push-in connection terminal with status indication for protecting one pair of unearthed signal circuits with a high nominal current for IT systems and measuring and control circuits. With signal disconnection for maintenance purposes.
Part No. 927254
BCO ML2 BD HC5A 24
New

€183.80

list price per item

item

BCO ML2 BPD 24

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair in 24 V DC systems. Also suitable for use with an earthed negative pole. Integrated PTC resistors allow for secure resetting of the arrester after interference in the system circuit with short-circuit currents of up to 40 A. With signal disconnection for maintenance purposes.
Part No. 927214
BCO ML2 BPD 24

€183.80

list price per item

item

BCO ML2 MVG 230

Space-saving, modular surge arrester with a width of 6 mm and push-in connection technology with status indication for protecting 2 lines of stranded unearthed signal interfaces with a nominal voltage of 230 V. With signal disconnection for maintenance purposes.
Meets, amongst other things, the requirements for signalling systems in the railway industry (e.g. DB RIL 819.0808 railway directive).
Part No. 927290
BCO ML2 MVG 230

€214.30

list price per item

item

BCO ML2 BD EX 24

Space-saving, modular combined arrester with a width of 6 mm and push-in connection technology with status indication for protecting one pair of intrinsically safe measuring circuits and bus systems, meets FISCO requirements. Insulation strength > 500 V core-earth. With signal disconnection for maintenance purposes.
Part No. 927284
BCO ML2 BD EX 24

€192.60

list price per item

item

BCO ML2 B EAS EX 15

Space-saving, modular combined arrester with a width of 6 mm and push-in connection system with status indication for protecting intrinsically safe Ethernet APL interfaces, PROFIBUS PA and measuring and control circuits. Fulfils the requirements of 2-WISE and FISCO Insulation strength > 500 V line-earth With signal disconnection for maintenance purposes.
Part No. 927280
BCO ML2 B EAS EX 15
New

€160.00

list price per item

item

BCO MOD ML2 B

Protection module with a width of 6 mm for BLITZDUCTORconnect lightning current arrester with status inidication for protecting two single lines for lightning equipotential bonding as well as indirect earthing of shielded cables.
Part No. 927010
BCO MOD ML2 B 180

€81.10

list price per item

item

BCO MOD ML2 BE

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927022
BCO MOD ML2 BE 12

€118.60

list price per item

item

BCO MOD ML2 BE

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927024
BCO MOD ML2 BE 24

€118.60

list price per item

item

BCO MOD ML2 BE

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927025
BCO MOD ML2 BE 48

€118.60

list price per item

item

BCO MOD ML2 BE

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting two single lines sharing a common reference potential as well as unbalanced interfaces.
Part No. 927027
BCO MOD ML2 BE 180

€118.60

list price per item

item

BCO MOD ML2 BD

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting one pair of unearthed balanced interfaces.
Part No. 927042
BCO MOD ML2 BD 12

€118.60

list price per item

item

BCO MOD ML2 BD

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting one pair of unearthed balanced interfaces.
Part No. 927044
BCO MOD ML2 BD 24

€118.60

list price per item

item

BCO MOD ML2 BD

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting one pair of unearthed balanced interfaces.
Part No. 927045
BCO MOD ML2 BD 48

€118.60

list price per item

item

BCO MOD ML2 BD

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting one pair of unearthed balanced interfaces.
Part No. 927047
BCO MOD ML2 BD 180

€118.60

list price per item

item

BCO MOD ML2 BE HF

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting two single lines of high-frequency transmissions sharing a common reference potential as well as unbalanced interfaces.
Part No. 927070
BCO MOD ML2 BE HF 5

€129.00

list price per item

item

BCO MOD ML2 BE HF

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting two single lines of high-frequency transmissions sharing a common reference potential as well as unbalanced interfaces.
Part No. 927074
BCO MOD ML2 BE HF 24

€129.00

list price per item

item

BCO MOD ML2 BD HF

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting one pair of unearthed high-frequency bus systems as well as balanced interfaces.
Part No. 927071
BCO MOD ML2 BD HF 5

€129.00

list price per item

item

BCO MOD ML2 BD HF

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arrester with status inidication for protecting one pair of unearthed high-frequency bus systems as well as balanced interfaces.
Part No. 927075
BCO MOD ML2 BD HF 24

€129.00

list price per item

item

BCO MOD ML2 BD HC5A 24

Combined arrester protection module with a width of 6 mm for BLITZDUCTORconnect with status indication for protecting one pair of unearthed signal circuits with a high nominal current for IT systems and measuring and control circuits.
Part No. 927054
BCO MOD ML2 BD HC5A 24
New

€118.60

list price per item

item

BCO MOD ML2 BPD

Combined arrester protection module with a width of 6 mm for BLITZDUCTORconnect with status indication for protecting one pair in 24 V DC systems. Also suitable for use with an earthed negative pole. Integrated PTC resistors allow for secure resetting of the arrester after interference in the system circuit with short-circuit currents of up to 40 A.
Part No. 927014
BCO MOD ML2 BPD 24

€118.60

list price per item

item

BCO MOD ML2 MVG 230

Surge arrester protection module with a width of 6 mm for BLITZDUCTORconnect with status indication for protecting 2 lines of stranded unearthed signal interfaces with a nominal voltage of 230 V.
Meets, amongst other things, the requirements for signalling systems in the railway industry (e.g. DB RIL 819.0808 railway directive).
Part No. 927090
BCO MOD ML2 MVG 230

€171.40

list price per item

item

BCO MOD ML2 BD EX 24

Protection module with a width of 6 mm for BLITZDUCTORconnect combined arresters with status indication for protecting one pair of intrinsically safe measuring circuits and bus systems, meets FISCO requirements. Insulation strength > 500 V line-ground.
Part No. 927084
BCO MOD ML2 BD EX 24

€126.00

list price per item

item

BCO MOD ML2 B EAS EX 15

BLITZDUCTORconnect combined arrester/protection module with a width of 6 mm with status indication for protecting intrinsically safe Ethernet APL interfaces, PROFIBUS PA and measuring and control circuits. Fulfils the requirements of 2-WISE and FISCO Insulation strength > 500 V line-earth
Part No. 927080
BCO MOD ML2 B EAS EX 15
New

€103.90

list price per item

item

PARTITION EXI

Special installation conditions have to be taken into account when using the BLITZDUCTORconnect surge protective devices in intrinsically safe electric circuits. According to EN 60079-11; 2007 (VDE 0170-7), a minimum clearance must be maintained between intrinsically safe and non-intrinsically safe signal circuits (connecting parts, e.g. connection clamps) of ≥ 50 mm! When using PARTITION EXI, this clearance is also maintained if the surge protective devices are arranged directly next to one another. Ideally suited for use in conjunction with DRC IRCM for condition monitoring of BCO modules. (1 pack = 2 pieces)
Part No. 910797
PARTITION EXI

€38.60

list price per Pack