datapoints.modbus.device.add datapoints.modbus.device[last].description=DEHNdetect datapoints.modbus.device[last].endianess=middle_cdab datapoints.modbus.device[last].type=tcp datapoints.modbus.device[last].tcp_port=502 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Out1 datapoints.modbus.device[last].datapoint[last].datapoint_type=discrete_input datapoints.modbus.device[last].datapoint[last].datapoint_register=0 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Out2 datapoints.modbus.device[last].datapoint[last].datapoint_type=discrete_input datapoints.modbus.device[last].datapoint[last].datapoint_register=1 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Out3 datapoints.modbus.device[last].datapoint[last].datapoint_type=discrete_input datapoints.modbus.device[last].datapoint[last].datapoint_register=2 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Out4 datapoints.modbus.device[last].datapoint[last].datapoint_type=discrete_input datapoints.modbus.device[last].datapoint[last].datapoint_register=3 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=In1 datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=0 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=In2 datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=1 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=In3 datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=2 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=In4 datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=3 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=ResetQtotal datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=10 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=ManTrigger datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=11 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=AmplifierSelfTest datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=12 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=AdjistInput datapoints.modbus.device[last].datapoint[last].datapoint_type=coil datapoints.modbus.device[last].datapoint[last].datapoint_register=14 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=EventNr datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=0 datapoints.modbus.device[last].datapoint[last].datapoint_format=sint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=TriggerEvent datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=2 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Charge in As datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=3 datapoints.modbus.device[last].datapoint[last].datapoint_format=float64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Energy in kJ/Ohm datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=7 datapoints.modbus.device[last].datapoint[last].datapoint_format=float64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=MaxCurrent in kA datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=11 datapoints.modbus.device[last].datapoint[last].datapoint_format=float64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=MaxRise in kA/ms datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=15 datapoints.modbus.device[last].datapoint[last].datapoint_format=float64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Qtotal in As datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=19 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=EventDateTime datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=23 datapoints.modbus.device[last].datapoint[last].datapoint_format=float64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=EventSampleTime in µsec datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=27 datapoints.modbus.device[last].datapoint[last].datapoint_format=float64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BladeEventNr datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=100 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BladeNr datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=102 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BladeStrength datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=103 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BladeEventDateTime datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=104 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=200 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_SerNum datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=201 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_FPGAVers datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=203 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=204 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=6 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=6 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_CPUTemp in 0,1° datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=208 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_FreeSpace in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=209 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_OpMode datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=210 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_Capturing datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=211 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU1_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=300 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=6 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU1_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=304 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU1_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=308 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU1_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=309 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU2_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=310 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU2_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=314 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU2_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=318 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU2_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=319 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU3_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=320 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU3_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=324 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU3_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=328 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU3_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=329 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU4_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=330 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU4_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=334 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU4_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=338 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU4_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=339 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU5_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=340 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU5_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=344 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU5_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=348 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU5_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=349 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU6_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=350 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU6_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=354 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU6_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=358 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU6_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=359 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU7_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=360 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU7_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=364 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU7_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=368 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU7_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=369 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU8_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=370 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU8_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=374 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU8_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=378 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU8_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=379 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU9_MACaddress datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=380 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=8 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU9_LastSeen datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=384 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU9_BatChrarge in % datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=388 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=BDU9_Version datapoints.modbus.device[last].datapoint[last].datapoint_type=input_register datapoints.modbus.device[last].datapoint[last].datapoint_register=389 datapoints.modbus.device[last].datapoint[last].datapoint_format=bytearray datapoints.modbus.device[last].datapoint[last].datapoint_string_length=2 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length=2 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=SampleRate in kHz datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=0 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Duration in msec datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=1 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Pretrigger in % datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=2 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=PreSamples1 datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=3 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=PreSamples2 datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=5 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=CcLimit in % datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=7 datapoints.modbus.device[last].datapoint[last].datapoint_format=float32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=CcDiscardThrHold datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=11 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Trigger1Level datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=13 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Max Q in As datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=17 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Max Q Total in As datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=19 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint32 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint[last].datapoint_bytearray_length= datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=Reboot datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=100 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint16 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10 datapoints.modbus.device[last].datapoint.add datapoints.modbus.device[last].datapoint[last].datapoint_description=DDL_SysTime datapoints.modbus.device[last].datapoint[last].datapoint_type=holding_register datapoints.modbus.device[last].datapoint[last].datapoint_register=200 datapoints.modbus.device[last].datapoint[last].datapoint_format=uint64 datapoints.modbus.device[last].datapoint[last].datapoint_string_length=10